Page 1 - How to make deliver y and

How to make deliver y and inst allation of your new h ot t ub fast, easy and trouble-free. PRE-DELIVERY

Page 2 - Warranty Valid

8Electrical Tasks Before Spa DeliveryIf installing a spa that is … Then it must be …240V (North America) Hard wired to the power supply.120V (USA only

Page 3 - Table of Contents

9❐Verify the power supplied to the spa is on a dedicated circuit with no other appliances or lights sharing the power.❐Verify the electrician has comp

Page 4 - Where should I install

10Important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid da

Page 5

11Important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid da

Page 6

12Power Configurations for 880 Capri Models (North America, 60Hz)This section describes the power configuration choices (Standard 50 Amp, and Alternat

Page 7

13Important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid da

Page 8

14Power Configurations for 780 Camden Models (North America, 60Hz)This section describes the power configuration choices (Standard 50 Amp and Alternat

Page 9 - Check the number of

15Power Configurations for 780 Certa, Chelsee, and Hamilton Models (North America, 60Hz)This section describes the power configuration choices (Standa

Page 10 - Continued on next page

16Important: All of the alternative electrical congurations require a qualied technician to perform minor circuit board modications. To avoid damag

Page 11 - To Keep Warranty Valid

17Power Configurations for 680 Burlington Models (North America, 60Hz)This section describes the power configuration choices (Standard 50 Amp and Alte

Page 12 - Config. #2

Please read this booklet before your scheduled delivery day.Record your spa information below and then store this booklet in a place you can easily fi

Page 13 - Config. #1

18 Important: All of the alternative electrical configurations require a qualified technician to perform minor circuit board modifications. To avoid d

Page 14

19Electrical Tasks After Spa Delivery+ Important safety information for all spa modelsProper grounding is extremely important. This spa is equipped wi

Page 15

20Installing a 3-Wire 240 VAC Connection for 880 Altamar, Cameo, Capri, Majesta, Marin, Maxxus, Optima Models, 780 Camden, Certa, Chelsee, Hamilton Mo

Page 16 - Config. #2

21Installing a 3-Wire 120 VAC or 4-Wire 120/240 VAC Connection for 780 Dover Models, 680 Denali, Tacoma ModelsElectrical Tasks After Spa Delivery, Con

Page 17

22Final Electrical ConnectionsNow, you can have the final electrical connections made to your spa. Various wiring diagrams are illustrated on the next

Page 18

23A pressure sensitive terminal block (bonding lug) is attached to the outside surface of the load box. This permits the connection of a bonding wire

Page 19

24PigtailNeutral BusGroundTB2TB1Black (L)White (N)GreenMainServicePanelwithGFCI1-Pole GFCIBreakerGround/Bonding Lug**1-Pole Circuit Breaker with 3-Wir

Page 20

25Connection Configuration #3 240 VAC Connections for Denali, Dover, Tacoma Models (North America 60 Hz)Red (L2)PigtailNeutral BusGroundTB2TB1Black (

Page 21 - Task Action

26Spa Dimensions and SpecificationsContinued on next pageUseful Details About the SpaThe tables below provide the spa dimensions and specifications th

Page 22 - Black (L1)

27680 SeriesModel Width Length Depth Filled Weight Min. Pad SizeBurlington81 in. (206 cm)86 in. (218.5 cm)37.5 in. (95.5 cm)4249 lb. (1927 kg)4 in

Page 23

1Congratulations! You’ve purchased a Sundance® spa, made to exacting ISO 9001 quality standards. With a little preparation and care, your spa will giv

Page 26 - (North America 60 Hz)

P/N 6890-558T, Rev. A 06/08©Sundance Spas, Inc. Pre-delivery Guide, Inc. All rights reserved.www.sundancespas.com800.899.7727

Page 27 - Connection Configuration #3

2Planning the Best Location for Your SpaWhere should I install the spa?When deciding where to place your spa, it should be:Moved away from overhead po

Page 28 - Useful Details About the Spa

3NoteIf the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result. Damage caused by a

Page 29 - , Continued

4How will I use the spa?Consider how you intend to use your spa.If using the spa for … Then …Family recreation Leave plenty of room around the spa for

Page 30

5Planning the Best Location for Your Spa, ContinuedSuggestions for Indoor Spa InstallationIf you are installing your spa indoors, take into considerat

Page 31

6Planning to Move the Spa Into Your YardUse the information below, in Figure 2, and in the Spa Dimensions and Specifications chart to plan the deliver

Page 32 - P/N 6890-558T, Rev. A 06/08

7Check protruding meters, fixtures, and rain gutters.Check overhang clearances.Check all gates and entries for width clearance.Be aware of other struc